Model: | RS-P-4D11K |
---|---|
Brand: | U-TONE |
Origin: | Made In China |
Category: | Metallurgy , Mining & Energy / New Energy / Solar Energy |
Label: | Solar Water Pump Co , Controller , Inverter |
Price: |
US $6200
/ pc
|
Min. Order: | 10 pc |
RS-P-4D11K3PH AC 11kw Solar Water Pump Controllers ~ Vector & MPPT & Modbus | ||||
Specifications | ||||
RS-P-4D11K Solar Water Pump Controller can accept Solar DC Power input, three-phase 380~480V inputs; Can drive 3PH AC Motor Pump | ||||
RS-P-4D11K 3PH AC Solar Water Pump Controllers | ||||
Function: Vector & MPPT & Modbus | ||||
Input: Three−phase 380 ~ 480V 50Hz/60Hz ; PV Area Voc DC700V±50V | ||||
Output: Three phase AC 380V, voltage adjustable | ||||
Able drive: 3PH AC motor, Below 12KW | ||||
Product introduction | ||||
RS−P Solar Water Pump Controller can accept PV input, single phase 220V and three-phase 380V inputs. It uses clean solar energy that is environment friendly and unlimited. It can also be powered by emergent diesel engine or grid power, and have variable frequency and energy saving features. | ||||
System components | ||||
The system mainly has 3 parts: power supply, controller and load. The power supply is PV (Photovoltaic) array, generator or grid. The controller is mainly the RS−P Solar Water Pump Controller. The loadis 3-phase asynchronous motor or pump. The system does not need battery for storing energy, which not only cuts the cost, but also protects the environment. RS−P PV Pump Controller can directly drive various kinds of 3-phase asynchronous motor, with high power integration and less components, which improves the system reliability. | ||||
Operating principles | ||||
RS−P series controller converts DC into adjustable 3-phase AC and can track the maximum power change of PV panel array. The maximum peak power tracking (MPPT) technology ensures the input power to be at the peak power all the time. The tracking range is adjustable, which flexibly utilizes the PV characteristics of solar cells. The vector control technology can perform auto learning to 3-phase asynchronous motor, which increases the efficiency of the controller to 93% to 99%, and fully uses the solar energy. The controller can be powered by solar energy, single phase 220V or 3-phase 380V grid power. In addition, the control terminalprovides rich extension functions to realize flexible system application scope. | ||||
RS−P−4D11K Three−phase AC power & PV DC power | ||||
Power (W) | 11K | |||
Motor | 9.2 | |||
power (kW) | ||||
Output | Voltage (V) | Three−phase AC 0 ~ Rated Input AC voltage | ||
Rated current (A) | 22 | |||
Overload | 150%: 1 minute, 180%:10 second, 200%: 0.5 second, interval: 10 minutes (inverse time lag feature) | |||
Input | RatedVoltage/Frequency | Three−phase 380V ~ 480V 50Hz/60Hz ; | ||
PV Area Voc DC700V±50V | ||||
Allowable | MPPT Area DC530~600V, Maximum DC780V | |||
Three−phase 323V to 528V, Voltage imbalance: ≤3%, allowable frequency fluctuation: ±5% | ||||
RatedCurrent | AC | 24.2 | ||
(A) | DC | 26.4 | ||
Protection class | IP20 | |||
Cooling mode | Natural−cooling | |||
Terminal functions | ||||
Terminal symbol | Terminal name and function description | Technical specifications | ||
Power supply | AC−IN | Three−phase or single phase AC input terminal | Three−phase 380V or single phase 220V AC
input terminal |
|
DC+ DC− | DC input + | DC 340Vdc or 650Vdc input | ||
AC−OUT | Three−phase AC output terminal U / V / W/PE | Three−phase 0 to 220V or 0 to 480V | ||
Three−phase input terminal, any two phases | Single phase 220V input | |||
PE | Controller and motor must be grounded | |||
COM terminal | DI | X4 / X5/ Com | Water level protection sensing terminal | X4: sensing terminal of water tower; X5: sensing termina
l of well; Com: common terminal |
*X1 to X7/DI | Multi function input or pulse input | Input specification: 24VDC ±20%,5mA,0 to 200Hz, | ||
External RS485 | *CN7 | RS485 for operation panel | Max cable length between the host computer
and RS485is 15m. |
|
*RS485+ / − / GND | Shielded layer of COM RS485+/- is grounded. | Baud rate: 4800/19200/38400/57600bps | ||
AI | *+10V | AI reference voltage | 10V±3%; 10mA maximum output current; overload
and short circuit protection |
|
*AI1/AI2/AI3 | AI 1, 2, and 3 | 0 to 20mA 500Ω / 0 to 10v 20kΩ / −10v to 10v 20kΩ | ||
DC power | *+24V / Com | +24V power | 24V±10% maximum load: 200mA, overload and
short circuit protection |
|
Relay | *RA/RB/RC | Relay output | RA−RB: NC; RA−RC: NO; Contact capacity:
250VAC/1A,30VDC/1A |
|
Note: The item marked with “*” is the customized item and some models do not have all the functional terminals, and please confirm this
with local dealer. |
||||