 1.  Introduction:

New Air intelligent controller (KF-800M) can monitor real-time indoor temperature, CO2 concentration. Controller output signal can directly control the startup and speed of ventilator. It can be widely used in residential, commercial and industrial applications, and can effectively improve air quality, create a healthy, comfortable, energy-efficient living and working environment.

 

2. Buttons’ function:

1.  button: timing parameter setting

2.  button: parameter increase

3.  button: parameter reduce    

4.  button: setting working mode for controller, press this button slightly, the controller will be switched circularly between “AUTO MANUAL TIMER POWER OFF”. 

 

3. Display explanation:

 
 
 


                                                                           Time

                                                                                   

 

 Indoor temperature                                                          CO2 concentration

 

 

                                                      Heating switch mode

   Operating mode

                                                       Ventilator status

4. Detailed explanation

1. AUTO (auto mode): high speed: CO2 concentration exceeds the setting concentration value of 300ppm; middle speed: CO2 concentration exceeds the setting concentration value of 100ppm; low speed: CO2 concentration exceeds the setting concentration value; stop: CO2 concentration is below the set concentration value.

2. MANUAL: set the ventilator as OFF(stop)LOW(low speed)MED(middle speed)HIG((high speed))by buttons  and , and under this mode, the ventilator will run according to the setting, won’t be affected by CO2 concentration.

3. TIMER (timing mode): run according to set time & speed, can set from Monday to Sunday, 4 periods every day, and 28 periods in total.

4. Automatic mode –concentration value setting when the ventilator starts: under the auto mode, press  or  button for one second, it will appear CO2 concentration setting value and flicker, then press  and  buttons to change the number (from 350 – 600ppm). Controller will return to normal working condition and save setting parameter automatically if you won’t press any buttons more than 10 seconds during the setting process.

5. Timing parameter setting: press  button for 2 seconds to enter parameter setting. First enter “local time adjust”, press  button to switch week, hour and minute, the corresponding parameter will flicker, change the number by  and  buttons; after finishing adjusting local time, press  button to enter the first period hour setting on Monday, press  button to switch hour, minute, and ventilator speed, press  and  buttons to change the number. After finish the setting, press  button to enter the second period hour setting on Monday…. Repeat above steps to finish all the 28 periods setting. Controller will return to normal working condition and save setting parameter automatically if you won’t press any buttons more than 10 seconds during the setting process.

6. Backlight: CO2 concentration less than 500ppm (green backlight), 500-799ppm (yellow backlight), higher than 800ppm (red backlight).

 

5. Specification

* Dimension:  86×86×40mm                               * Warm-up time: 1 minute

* Fixing hole distance: 60mm(standard)                * Response time:  10 seconds

* Wiring terminal: Max 2.5 mm2 wire               * Recovery time:       30 seconds 

* Rated voltage: AC220V 50Hz                                * Operating temperature:   -10 --- +50 

* Standby Power: 0.5W                                         * Operating humidity: 5RH——90RH

* Control power: 200W                                         * Storage temperature: -10 --- +60 

* Output interface: Three-speed ventilator                 * Storage humidity: 60RH

* Temperature display range: 0——50                   * Life: 10 years

* CO2 display range: 350ppm——3000ppm

Product Image

heat exchanger switch KF-800M 1
Img 1

Send Inquiry to this Member

Shenzhen Viewpu Technology Co., Ltd

Room 305-307, Building 9 of Wangtang industrial park, No. 22 of Tongsha Road, Xili Town, Nanshan district, Shenzhen, China.

Phone:
0086-755-86546022
Fax:
86-755-86546099
Contact:
Elva Zhu (Sales)
Mobile:
13480891729

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Heat Exchange & Air Conditioners Made In China Products

,  

Heat Exchange & Air Conditioners China Suppliers and China Manufacturers