Home > Products > Electronics & Electricity > Electronic Instrument > Analysis Instrument

V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen 1V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen 2
  • V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen 1
  • V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen 2

V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen

Model:V-Sorb 2800TP
Brand:Gold APP Instruments
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:surface area , nitrogen adsorption , pore volume
Price: US $1 / set
Min. Order:1 set
Inquire Now Add to Basket

Member Information

Detail

Gold APP Instruments Co., Ltd.

Free MemberBeijing - China
Live Chat:
点击这里给我发消息Last Online:17 Apr, 2024

Product Description

V-Sorb 2800TP specific surface area and pore size analyzer introduction

V-Sorb 2800TP is Gold APP self-developed surface area and porosity analyzer which utilizes static volumetric. Compared with other companies’ analyzers, multi pioneered techs make instrument’s performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in domestic competitors and partial applications surpass foreign instruments. Products designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. The high cost performance of V-Sorb 2800TP easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.


V-Sorb 2800TP specific surface area and pore size analyzer parameters

  1. Analysis Method: static volumetric nitrogen adsorption
  2. Versatility: Adsorption and desorption isothermal curve analysis, Single and multi point BET method specific surface area analysis, Langmuir method specific surface area analysis, Average particle diameter estimation, T-plot method external surface area analysis, True density analysis, BJH total pore volume and pore size distribution analysis, T-plot method micropore analysis, MP method micropore analysis, HK method micropore analysis
  3. Vacuum System: V-sorb unique stainless steel micro welding vacuum manifolds system, metal-to-metal (VCR) fittings, reduce dead space in maximum degree and also keep long duration high vacuum; the VCR metal fittings’ vacuum leak rate can reach 1x10-10 (Pa*m3/s), absolutely without usage of any O-ring sealing which will release gas to affect vacuum purity when under high vacuum condition
  4. Vacuum Cavity: V-sorb unique assembling-installed manifolds and electromagnetically operated valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life
  5. Measurement Modes: “N2” and standard “N2+He” modes are available. The “N2+He” mode accords with international criterion, can guarantee the accuracy and consistence; it is not suitable to employs He to measure free space due to some samples can adsorb He in low temperature, but, ideal analysis results can get by using “N2” mode
  6. Gas Dosing: Can choose He (99.999%) to dose the cold volume, not only “He+Empty cell” one type
  7. Measuring Ranges: 0.01m2/g to no known upper limit(specific surface area), 0.35 to 2nm (micropore), 2-500nm (mesopore and macropore)
  8. Accuracy: repeatability errors ≤1.5%
  9. Coolant Level Controller: V-sorb original coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change
  10. Data Acquisition: high-precision and high integration data acquisition and archiving system, minimal error, strong anti-interference ability
  11. Sample Ports: two samples’ analyzing and two samples’ degassing concurrently
  12. Control System: programmable controller electromagnetically operated valve system with high integration and strong anti-interference ability, enhance instrument’s stability and life
  13. Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)
  14. Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
  15. Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop
  16. Dewar Vessel: imported 4 liter metal made Dewar can provide at least 72 hours of unattended measurement without refilling the Dewar
  17. Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.995
  18. Ultimate Vacuum: bipolar pump: 4x10-2Pa (3x10-4Torr), molecular pump: 5x10-6Pa
  19. Sample Types: powders, particle, fiber, flakes and other materials
  20. Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr etc. optional
  21. Data Reduction: Windows®-base independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports

 

 

V-Sorb 2800TP specific surface area and pore size analyzer features

  1. Stainless steel micro welding vacuum manifolds system can reduce the leak rate apparently, improve ultimate vacuum, without daily maintenance and enhance stability.
  2. Micro welding vacuum system can decrease manifolds’ volume, increases measuring sensitivity and raise accuracy.
  3. Imported with original packaging molecular pump, ultimate vacuum can reach 5x10-6-0.995, maintenance free, convenient to use, reduce latter utilization cost.
  4. Micro welding vacuum system, high vacuum electromagnetically operated valve and high ultimate vacuum molecular pump unite perfectly, bring each accessories performance into full play, precision degree can reach until 5x10-8.
  5. Imported high vacuum pneumatic valve's sealing performance is up to 5x10-12 (Pa﹡ m3/s), can completely remove analyzed gas temperature change caused by valve heat.
  6. Fully metal-to-metal VCR connecting can eliminate O-ring self gas release problem when under high vacuum circumstance, efficiently improve ultimate vacuum and analysis reliability.
  7. Imported high-precision silicon thin film capacitive transducer, the core part, can realize auto zero by software; the 1 Torr full-scale (F.S.) transducer assists micropore to achieve a more accuracy data for low P/Po points.
  8. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.
  9. Programmable controller electromagnetically operated valve system with high integration and strong anti-interference ability, speed and easy for upgrade and maintenance.
  10. Fully auto and modularity design, equipped with dedicated software, can realize unattended operation at night.
  11. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.


V-Sorb 2800TP specific surface area and pore size analyzer application

  1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.
  2. Product quality control for powder materials related corporations.
  3. Research institutes, universities for BET theory teaching.
  4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.
  5. Other researches concern surface area performance.

Product Image

V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen 1
Img 1
V-Sorb 2800TP BET surface area and pore volume analyzer by nitrogen 2
Img 2

Send Inquiry to this Member

Gold APP Instruments Co., Ltd.

Room 811, New Material Building, No. 7th, Fenghui Middle Road, Haidian District

Phone:
86-182-10009838
Fax:
86-182-10009838
Contact:
Mr. Andy (Sales Manager)
Mobile:
10009838

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Analysis Instrument Made In China Products

,  

Analysis Instrument China Suppliers and China Manufacturers