Home > Products > Security & Protection > Alarm

4-Wire Smoke Detector  with relay output 14-Wire Smoke Detector  with relay output 24-Wire Smoke Detector  with relay output 3
  • 4-Wire Smoke Detector  with relay output 1
  • 4-Wire Smoke Detector  with relay output 2
  • 4-Wire Smoke Detector  with relay output 3

4-Wire Smoke Detector with relay output

Model:JTY-GD-DG311
Brand:zc
Origin:Made In China
Category:Security & Protection / Alarm
Label:smoke alarm , smoke detector , heat alarm
Price: US $6.5 / pc
Min. Order:100 pc
Inquire Now Add to Basket

Member Information

Detail

ShenZhen Zoanco Electronics Co ., Ltd

Free MemberGuang Dong - China
Live Chat:
点击这里给我发消息Last Online:17 Jul, 2023

Product Description

1. GENERAL DESCRIPTION

The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel.

Two LEDs on each detector provide local 360° visible alarm indication. They flash every 5-6 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm,will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The detector can be restored to normal status automatically when the ambient smoke or temperature below the alarm value.

Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.

 

2. SPECIFICATIONS

Operating Voltage Range:                       9 to 28 VDC Volts Non-polarized

Standby Current:                ≤200µA

Maximum Alarm Current (LED on):   ≤45mA

Alarm Relay Contact Ratings:       1A@ 24V DC

Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing

Operating Temperature Range:        -10°C to 50°C (14°F to 122°F)

Smoke Alarm Sensitivity:          0.15~0.3dB/m

Temperature Alarm Sensitivity:       57°C (135°F) (only for with heat sensor)

Height:                       55 mm installed in Base

Diameter:                            103 mm

3. INSTALLATION

NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.

 

INSTALL THE DETECTOR BASE

1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country.

2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a square (100mm) box without using any type of mechanical adapter.

3. Position all wires flat against terminals, and fasten the wires on the terminals, See Figure 1.

4. Terminals function description:

Terminal 1: Relay Output -COM

Terminal 2: Relay Output – NO/NC (default NO)

Terminal 3: DC Power –

Terminal 4: DC Power +


Payment Terms:T/T,WU,PAYPAL

Product Image

4-Wire Smoke Detector  with relay output 1
Img 1
4-Wire Smoke Detector  with relay output 2
Img 2
4-Wire Smoke Detector  with relay output 3
Img 3

Send Inquiry to this Member

ShenZhen Zoanco Electronics Co ., Ltd

4F, Building B1, XinHaoSheng High-Tech Park, YongHe Road, FuYong Town, Baoan District, Shenzhen, China

Phone:
86-0755-23015236
Fax:
86-0755-23015236
Contact:
Jenny Ning (manager)
Mobile:
15220176087

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Alarm Made In China Products

,  

Alarm China Suppliers and China Manufacturers