Product Description
KDCL-100 series Biogas Purifying System |
1. Main Specificstions |
|
Model |
KDCL-100-WQ |
The suitable genset power |
80KW-120KW |
Dimension |
2000×2000×2240 (mm) |
Weight |
2800kg |
Gas flow |
80~120Nm3/hr |
Working pressure |
4~40KPa |
Desulfurizer amount |
2×300kg |
The changing time of desulfurizer |
1500 hours |
Parts per million after purifying |
200ppm |
The designed lifetime |
15years |
|
|
2. The Main Equipment |
|
1. Name |
Desulfurizing tower |
Qty |
2 unit |
Model |
KDTL-400-G |
Specifications |
Φ600×2000 |
Function |
Desulfurization |
2. Name |
Separator |
Qty |
1unit |
Model |
KDFC-300-G |
Function |
1. Gas buffter;2. De-Dust |
3. Name |
Water condenser |
Qty |
1unit |
Model |
KDYS-20-G |
Function |
De-water before desulfurizing tower |
3. Name |
Blower |
Qty |
1unit |
Model |
NSR65-65A |
Specifications |
1.5KW |
Function |
Increase pressure and steady pressure |
|
|
3. The main function of this system |
1. Desulfurization |
|
2. De-dust |
|
3. De-water |
|
4. Increase pressure |
|
5. Steady pressure |
|
6. Change desulfurizer without stopping genset |