This Co. have total
4
Related Items
| 1234Next |
|
(1) Discharged gasoline volume: >50 L/min(Heavy Duty:5~85 L/min)
(2) Accuracy: ±0.3%
(3) Pumping distance: 4m
(4) Working Ambient:
1) Adapt temperature: -30℃~ +70℃
2) Relative humidity: <95%
3) Air pressure: 86~106kpa
(5) Power Supply:
1)Voltage: AC220V±20% □
AC380V±20% □
2) Frequency: (50/ 60)Hz
(6) The digits number displayed on display screen:
1) Liter district: 6 digits
2)Amount district: 6 digits
3)Unit price district: 4 digits
(7) Unit price setting range:
0.00~999.9 basic currency(e.g. $) / liter
(8) Counting range for one refueling:
1) Volume: (0.00—9999.99) liters
2) Amount: $(0.00—99999.9)
(10) Counting range for preset filling quantity
1) Preset volume: (0.50—9999.99) liters
2) Preset amount
① If unit price is $ (0.00~9.99)/liter, then
Preset amount: $(0.00—9999.99)
② If unit price is more than $10.00/liter, then
Preset amount: $(0.0—99999)
(11) Counting range of accumulative totals:
Volume: (0.00—99999999.99) liters
Amount: $(0.00—9999999999.99)
(12) Counting range of shift accumulative totals:
Volume: (0.00—99999999.99)liters
Amount: $(0.00—9999999999.99)
(13) Leaves the communication port, so it can communicate with the gas station management system.
(14) All important data shall be kept for ten year in case of power failure.
Explosion Protected symbol:ExmdⅡAT3
Explosion Protected Qualification Number. CNEx06.0717
License Number of manufacturing gauge:Anhui Manufacture00000145Number