PNOZ XV2 30 s 24 V DC 774 500 at SRINUTCH.COM
Emergency Stop Relays, Safety Gate Monitors
Category 4, EN 954-1
Emergency stop relay and safety
gate monitor in accordance with
VDE 0113 part 1, 11/98, EN 60204-1,
12/97 and IEC 204-1, 11/98.
Features
l
PNOZ X3
l
detection of shorts across the
input contacts
l
reset can be selected
l
l
Technical Details PNOZ XV2
Electrical Data
Supply Voltage 24 VDC
Tolerance 85 ... 110 %
Power Consumption U
Voltage and Current at the Input and 24 VDC, 50 mA
Reset Circuits and Feedback Control Loop
Switching Capability in accordance with
EN 60947-4-1, 10/91 AC1: 240 V/8 A/2000 VA
DC1: 24 V/8 A/200 W
EN 60947-5-1, 10/91 AC15: 230 V/5 A; DC13: 24 V/7 A
(DC13: 6 cycles/min.)
Output Contacts 2 delayed safety contacts (N/O)
2 instantaneous safety contacts (N/O)
Contact Fuse Protection 10 A quick or 6 A slow
(EN 60947-5-1, 10/91)
Times
Delay-on-De-Energisation 37-38, 47-48 Adjustable:
0,1-3 s: 0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/
1/1.5/2/3 s
0-30 s: 0/0.5/1/2/4/6/8/10/15/20/25/30 s
0-300: 0/5/10/20/40/60/80/100/150/200/
250/300 s
Fixed: 0.5 s, 3 s, 10 s
Delay-on Energisation Max. 50 ms
Delay-on De-energisation Max. 50 ms
Recovery Time Approx. 1 s
Simultaneity channel1/2
Max. Supply Interruption before Approx. 25 ms
De-energisation
Mechanical Data
Max. Cross Section of 1 x 2.5 mm
External Conductors Single-core or multi-core
with crimp connectors
Dimensions (H x W x D) 87 x 45 x 121 mm
Weight 370 g
Description
l
mounting
l
– 2 instantaneous safety contacts
(N/O)
– 2 delayed safety contacts
(N/O)
l
– E-STOP button
– safety gate limit switch
– reset button
l
channel 2, reset circuit
l
safety contacts available by
connecting expander modules.
PNOZ XV2
Operating Modes
l
l
l
l
General Technical Data
Unless stated otherwise in the technical details for the specific unit
Electrical Data
Frequency Range AC 50 ... 60 Hz
Residual Ripple DC 160 %
Contact Material AgSnO
Continuous Duty 100 %
Environmental Data
EMC EN 50081-1, 01/92, EN 50082-2, 03/95
Vibration in accordance with Frequency: 10 ... 55 Hz,
EN 60068-2-6, 04/95 Amplitude: 0.35 mm
Climatic Suitability DIN IEC 60068-2-3, 12/86
Airgap Creepage DIN VDE 0110 part 1, 04/97
Ambient Temperature -10 ... +55 °C
Storage Temperature -40 ... +85 °C
Mechanical Data
Torque Setting on Connection Terminals 0.6 Nm (screws)
Mounting Position Any
Housing Material Thermoplast Noryl SE 100
Protection Mounting: IP 54
Housing: IP 40
Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at
the time of development.
Order References
Type t U
PNOZ XV2 0,5 s fest 24 V DC 774 504
PNOZ XV2 10 s fest 24 V DC 774 506
PNOZ XV2 3 s 24 V DC 774 502
PNOZ XV2 3 s fest 24 V DC 774 505
PNOZ XV2 30 s 24 V DC 774 500
2B Order No.B Approx. 4.5 W¥245 mm P-97 housing, DIN RailPositive-guided relay outputs:Connections forLEDs for power, channel 1,Increase in the number ofSingle-channel operationDual-channel operationAutomatic resetMonitored manual resetInput wiring compatible with theDual-channel wiring withMonitored manual or automatic2 delay-off safety contactsSupply voltage: 24 VDC
|