PNOZ 16S 774073 at SRINUTCH.COM
Emergency Stop Relays, Safety Gate Monitors
Category 4, EN 954-1
Emergency stop relay and safety
gate monitor in accordance with
VDE 0113-1, 11/98, EN 60204-1,
12/97 and IEC 204-1, 11/98.
Features
l
with safety mats
Designed specifically for use
l
with 24 VDC
Each AC unit can be operated
l
outputs (Fault, K1/K2)
Technical Details PNOZ 16/PNOZ 16S
Electrical Data
Supply Voltage AC: 24, 42, 48, 110, 115, 120, 230, 240 V
DC: 24 V
Tolerance 85 ... 110 %
Residual Ripple DC 20 %
Power Consumption Approx. 2 W/3 VA
Voltage and Current at the Input and, 24 VDC, 50 mA
Reset Circuits and Feedback Control Loop
Switching Capability in accordance with
EN 60947-4-1, 10/91 AC1: 240 V/5 A/1200 VA,
DC1: 24 V/4 A/100 W
EN 60947-5-1, 10/91 AC15: 230 V/2 A; DC13: 24 V/3A
(DC13: 6 cycles/min.)
Output Contacts 2 safety contacts (N/O)
Contact Fuse Protection 6 A quick or 4 A slow
(EN 60947-5-1, 10/91)
Safety Mat Resistance Per channel < 40
Semiconductor Outputs 24 VDC/20 mA, PNP
External Supply Voltage 24 VDC -15/+10 %
Times
Delay-on Energisation Approx. 300 ms
Delay-on De-energisation Approx. 50 ms
Recovery Time
Switch-on Time
with automatic reset 0.1 ... 1 s ± 20 %
with manual reset 0.1 ... 0.5 s ± 20 %
after a short across the input contacts Approx. 100 ms
Simultaneity channel 1/2
Max. Supply Interruption before De-energisation
Mechanical Data
Maximum Cross Section of 2 x 1.5 mm
External Conductors Single-core or multi-core
with crimp connectors
Dimensions (H x W x D) 87 x 45 x 121 mm
Weight 330 g
Description
l
mounting
l
– 2 safety contacts (N/O)
l
– E-STOP button
– safety gate limit switch
– safety/pressure mat
– safe edges
l
channel 2 and external fault
l
safety contacts available by
connecting expander modules.
Operating Modes
l
l
l
l
Category 4, EN 954-1
PNOZ 16/PNOZ 16S
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-060-07/00
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
General Technical Data
Unless stated otherwise in the technical details for the specific unit
Electrical Data
Frequency Range AC 50 ... 60 Hz
Residual Ripple DC 160 %
Contact Material AgSnO
Continuous Duty 100 %
Environmental Data
EMC EN 50081-1, 01/92, EN 50082-2, 03/95
Vibration in accordance with Frequency: 10 ... 55 Hz,
EN 60068-2-6, 04/95 Amplitude: 0.35 mm
Climatic Suitability DIN IEC 60068-2-3, 12/86
Airgap Creepage DIN VDE 0110 part 1, 04/97
Ambient Temperature -10 ... +55 °C
Storage Temperature -40 ... +85 °C
Mechanical Data
Torque Setting on Connection Terminals 0.6 Nm (screws)
Mounting Position Any
Housing Material Thermoplast Noryl SE 100
Protection Mounting: IP 54
Housing: IP 40
Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at
the time of development.
Order References
Type U
PNOZ 16 24 V AC/DC 774 060
PNOZ 16 42 V AC/24 V DC 774 061
PNOZ 16 48 V AC/24 V DC 774 062
PNOZ 16 110 V AC/24 V DC 774 063
PNOZ 16 115 V AC/24 V DC 774 064
PNOZ 16 120 V AC/24 V DC 774 065
PNOZ 16 230 V AC/24 V DC 774 066
PNOZ 16 240 V AC/24 V DC 774 067
PNOZ 16S 24 V AC/24 V DC 774 070
PNOZ 16S 42 V AC/24 V DC 774 071
PNOZ 16S 48 V AC/24 V DC 774 072
PNOZ 16S 110 V AC/24 V DC 774 073
PNOZ 16S 115 V AC/24 V DC 774 074
PNOZ 16S 120 V AC/24 V DC 774 075
PNOZ 16S 230 V AC /24 V DC 774 076
PNOZ 16S 240 V AC/24 V DC 774 077
2B Order No.Wshort circuit protected³ 1 s¥Approx. 10 ms245 mm, P-93 housing, DIN RailPositive-guided relay outputs:Connections forLEDs for power, channel 1,Increase in the number ofSingle-channel operationDual-channel operationAutomatic resetManual resetPNOZ 16S: 2 semiconductor
|